E602 is a set of equipment units enclosed
into a stainless steel cabinet, performing all functions
needed for the automated control of
a high power lighthouse and for communication with
the remote monitoring and control centre.
The set consists of main system for the control
of lanterns up to 1000W power and of
reserve (secondary) system E601 for the control of reserve
lantern up to 100W power. The actual
configuration of the system is to be specified by the customer.
It is designed for the long-term operation
in field conditions.
Features
-
Flashing control of the main and reserve
lanterns and control of the lampchanger
-
Data exchange with the remote monitoring
and control centre
-
Daylight control of the flashing and immediate
sending of the ON/OFF switching times to the monitoring and control centre
and to the VTS
-
Synchronisation of flashing by the GPS
signals with a given time delay
-
Sending timing signals to the internal
units, connected by the local area network
-
Internal diagnostics of the system components
and testing of the power supply voltages, and sending warning or emergency
messages to the monitoring and control centre, if necessary
|
 |
-
Automatic switching over from the main
system to the reserve system E601 in case of failures
-
Control of power supply units and optimal
charging of batteries
-
Analysing of the state of 220V mains and
giving warning messages to the remote monitoring and control centre when
the voltage is less than 150V or greater than 270V
-
Automatic switching over to the accumulator
batteries and, if needed, to the reserve Diesel-Generator Station E179
in case of failure of mains supply
-
Remote setting up of the system from the
monitoring and control centre
Specification
Main
system components |
Power
converter 220V AC/140V DC E174
1000W flasher
E175
Power contactor
switch E176
Diesel generator
controller E177
Diesel generator
Interface converter
RS232/Echelon E401 (LAN gateways)
Cabinet “Braidos” |
Reserve
system E601 components |
Flasher
E863.1
Communication
controller E924 or E9202
GPS locator
E934 |
Input
voltage |
220V
50Hz AC |
Power
consumption |
1.5kW |
Power
of the Diesel-Generator |
2.6
kVA, suitable type YANMAR YDG3700 |
Voltage
of the main lantern |
110V
or 120V DC |
Power
of the lantern |
500W
or 1000W |
External
batteries, main |
120/132V,
charging current 10A max. |
Communication
media |
GSM-900,
NMT-450 or public switched telephone network |
Internal
local area network |
Echelon
LON, 78kbps; Abus, 9600bps |
Ambient
air temperature |
from
-30°C to +55°C* (IEC 60068-2-12,14), mobile phone communication garanteed
by the temperatures above -25°C |
Relative
humidity |
up
to 98% at temperature +35°C (IEC60068-2-3) |
Application
in salt mist conditions |
allowed
(IEC 60068-2-11) |
Dimensions |
525
x 930 x 380mm |
Download
the E602 catalogue page in Adobe pdf format
If you need more information, including
the information on prices and availability of our
products, please do not hesitate to contact
our marketing group.
|